A scour inspection answers one question: has the bed around this bridge moved since the last time anyone looked, and does that matter for the foundations? Every method below is a way of answering it. They differ in what they can see, in what water they work in, and in how much they cost to mobilize.

This list is for bridge owners, inspection program managers, and the engineers who read the reports. It covers inspection: periodic visits that measure the bed and the substructure. Instruments left in place to watch the bed continuously are a different subject, covered in our companion list on scour monitoring technologies.

The regulatory frame, briefly

Under the National Bridge Inspection Standards (23 CFR 650 Subpart C, as revised in 2022), an underwater inspection is an inspection of the underwater portion of a bridge substructure and the surrounding channel “which cannot be inspected visually at low water or by wading or probing, and generally requiring diving or other appropriate techniques.”

Under the simplified risk method in 23 CFR 650.311(b), the regular underwater interval is not to exceed 60 months. It drops to 24 months where the underwater condition, the channel or channel protection, or the observed scour condition is rated serious or worse (coded 3 or less), and can be extended to 72 months for bridges meeting defined good-condition criteria under a documented owner policy. A risk-based Method 2 sorts bridges into categories with limits of 24, 60 or 72 months, subject to FHWA approval.

Those are maximums. Where a bridge’s scour plan of action calls for more frequent or flood-triggered inspection, as HEC-18 recommends for scour-critical bridges, the plan governs.

How we ranked them

  • Does it produce a comparable measurement? HEC-18’s review of bridge failures concludes that inspectors must “measure, plot, and compare cross sections of the channel.” A method that cannot be repeated the same way next cycle is worth less.
  • Does it see the foundation, the bed, or beneath the bed? Those are three different things, and scour holes refill as floods recede.
  • Conditions it tolerates: depth, velocity, visibility, debris, air entrainment, salt water.
  • What it demands: crew qualifications, equipment, post-processing.

At a glance

#MethodSeesWorks bestMain limitation
1Plotted soundings and cross-sectionsBed elevation over timeEvery bridge, every cycleOnly as good as the baseline and consistency
2Diver inspection (Levels 1 to 3) with probingSubstructure condition, bed material, infillAnything too deep to wadeUnsafe in floods, high velocity, heavy debris
3Wading and hand probingSubstructure and bed in shallow waterLow-water inspections of small channelsOnly at low water; misses what is deeper
4Single-beam echo soundingBed profile under a track lineChannel profiles, repeat surveysAffected by air and heavy sediment; one line at a time
5Multibeam sonar3D bed and substructure surfaceLarge rivers, countermeasure design volumesGPS loss under the deck; heavy post-processing
6Scanning (2D) acoustic imagingPier faces, footing exposure, local holes, debrisTurbid water, dive planning, post-event checksHead must stay still; resolution falls with range
7Ground penetrating radar and tuned transducerInfilled scour beneath the present bedForensic look after a floodCost, interpretation; GPR limited in salt water and clays
8Remotely operated vehicle (ROV)Substructure visuals, sonar imageryStill water, depths near or beyond 100 fswImpractical in most river currents

1. Plotted soundings and channel cross-sections

The least glamorous method and the one that matters most. Depth readings around every submerged substructure and a profile along the upstream fascia, taken the same way every cycle and plotted against the as-built and previous inspections. The FHWA Underwater Bridge Inspection Reference Manual (FHWA-NHI-23-027, 2024) says soundings should be taken during each underwater inspection and that consistency between cycles is what makes them useful. Collection can be as simple as a weighted tape from the deck or as precise as a survey-grade system.

HEC-18’s account of the Hatchie River failure makes the case. Inspectors had measured bed depths at each substructure, but no channel profile was being maintained, so the evaluator could not see that the channel was migrating toward the bridge. Had the profiles been plotted, HEC-18 notes, the lateral migration should have been easy to detect.

Best fit: every bridge over water, as the baseline that every other method is compared against.

Worst fit: as a standalone answer after a flood. A sounding records today’s bed, and scour holes refill as flow drops. See post-flood scour inspection.

2. Diver inspection with probing

Still the core of an NBIS underwater inspection. The FHWA manual describes three levels of effort. Level 1 is a visual and tactile examination of all submerged surfaces, cleaning only where a defect is found. It includes probing the channel bottom around the substructure with a steel rod, because infill is usually looser than the natural bed and a probe penetrates it more easily, which lets the diver estimate how deep scour went during earlier high flows. Level 2 adds cleaning of selected areas; the manual suggests 10 percent of piles or columns on pile and column substructures. Level 3 adds detailed cleaning and non-destructive or partially destructive testing.

Divers can also do what sonar cannot: reach into an undermined area beneath a footing, measure how far it goes, and judge the condition of concrete, steel or timber by hand.

Best fit: the routine underwater inspection of any bridge too deep to wade, and any site where undermining is suspected.

Worst fit: flood conditions, heavy timber debris, high velocity and hazardous water, which the FHWA manual lists as the situations where divers may not be able to work safely. Those are exactly when scour is worst, which is why items 5 to 7 exist.

3. Wading and hand probing

The NBIS definition of an underwater inspection starts where wading and probing stop, which makes this the method of choice for small, shallow channels. An inspector in waders with a probe rod and a tape can check pile condition, measure bed elevation and find soft infill around a bent at low water.

Best fit: shallow streams inspected during low flow, as part of the routine inspection.

Worst fit: anything deeper than a safe wading depth, and any inspection timed so that the channel is only wadeable because the flow is low. Low water can hide the conditions that matter.

4. Single-beam echo sounding

A transducer sends an acoustic pulse to the bed and times the return. HEC-23 notes that frequencies around 200 kHz are typical for scour work and that single-beam sonar ranges from low-cost fish finders on a tethered float to survey-grade hydrographic sounders. Deployed from a boat, a kneeboard float, or a crane arm from the deck, it produces continuous profiles rather than discrete probe points.

Best fit: repeatable channel profiles and bathymetric surveys around piers, especially where the channel is too deep or wide to probe efficiently.

Worst fit: heavily aerated or sediment-laden flow, which HEC-23 says can degrade sonar returns, and any job that needs to see beneath the present bed. Sonar sees the water-bed interface, not the infill below it.

5. Multibeam sonar

A multibeam system transmits and receives many beams at once and builds a three-dimensional point cloud of the bed and the submerged structure. The FHWA manual notes the main advantage: volumes can be calculated, which helps when a countermeasure is being designed. It also notes the main drawbacks. Collection while moving needs continuous GPS, which can drop out beneath the superstructure, and the data can require significant post-processing.

Best fit: large rivers and estuaries, documenting the full extent of a scour hole before designing a repair, and establishing a detailed baseline after construction.

Worst fit: small channels where a boat cannot operate, low-clearance bridges, and budgets that cannot absorb the processing time.

6. Scanning (2D) acoustic imaging

A rotating sonar head is fixed in one position, often clamped to a vessel or the pier, and sweeps to build an image of the pier face and the bed around it. The FHWA manual describes it as useful for documenting footing and seal exposure, the depth of local holes, and debris, and says acoustic imaging can work at ranges beyond 300 feet and in turbid water where cameras are useless. It is also used to plan dives by locating entanglement hazards and undermined areas before a diver goes in.

Best fit: low-visibility water, pre-dive hazard checks, and rapid post-event looks when diving is unsafe.

Worst fit: fine defects such as narrow cracks, which the manual says are generally not visible in acoustic images, and conditions where wave action or strong current keep the head from staying still. Air bubbles near the head also degrade the image.

7. Ground penetrating radar and tuned transducer (sub-bottom methods)

Because infill differs in density from the undisturbed bed, a sub-bottom method can find the interface and show how deep a hole went before it refilled. The FHWA manual describes GPR as usable on land or in relatively shallow water (less than 25 feet), and gives an example where a hole that soundings put at about 7 feet deep had, by GPR, been about 16 feet deep at some point. The tuned transducer, or low-frequency sonar, is a seismic system that penetrates the bed acoustically.

HEC-23 adds the limits: GPR does not work well in dense, moist clays or salt water; seismic signals are scattered by air bubbles and high sediment concentrations; both are costly and need skilled interpretation. It calls geophysics best used as a forensic tool after the flood.

Best fit: answering “how deep did it get?” at a scour-critical bridge after a significant event.

Worst fit: routine surveys on every bridge, tidal and saline crossings for GPR, and any program without someone trained to interpret the records.

8. Remotely operated vehicles

An ROV carries cameras and, on some units, sonar and manipulator arms. The FHWA manual says ROV inspections are generally limited to water with very little current, such as lakes, reservoirs and ocean settings, that turbulence around piers makes them impractical in most rivers, and that at depths of 100 fsw or more an ROV can be a safe, cost-effective alternative when the owner approves it.

Best fit: deep reservoir, lake and marine crossings.

Worst fit: riverine piers in current, which is where most scour happens.

Which combination for which bridge

  • Small stream crossing: wading and probing at low water, plotted against the previous cycle.
  • Typical river bridge: diver Level 1 with probing, plus soundings or a single-beam profile every cycle.
  • Scour-critical bridge after a flood: acoustic imaging if diving is unsafe, then diver probing, then GPR or tuned transducer if the question is how deep it went. See scour critical bridges.
  • Before designing a countermeasure: a multibeam survey of the hole, then a careful read of the scour evaluation.
  • After a countermeasure goes in: a new baseline survey, then post-installation inspection with close attention to the perimeter of the armor.

What inspection finds, and what comes next

An inspection that finds lowering at a pier leads to a decision: monitor, repair, or both. The protection options are compared in our list of best bridge scour protection products, and the history of what happens when findings are missed is in lessons from major bridge scour failures. FES Solutions makes rock bags used as one of those repair options, covered on our bridges application page; nothing on this list depends on which product follows.

If an inspection report has landed on your desk and you want a second read on what the soundings mean for protection, get in touch.

FES Solutions is a supplier, not the engineer of record. This article is general engineering background, not a site-specific design. Conditions vary, and the design decision for your project belongs to the engineer of record. Where rock bags are not the right answer.

Written by
Mike Jones
Engineering Manager, FES Solutions

Mike Jones is Engineering Manager at FES Solutions. He holds a BS in civil engineering and an MS in hydrology, and spent 15 years with engineering firms and as an independent consultant on drainage and erosion control projects.

Specifying scour protection?

Tell us the site conditions and we'll come back with sizing, lead time, and pricing within one business day.

Call