Skip to main content
Storm-season scour checklist
FES Solutions — Texas Tuff Rock Bags
Engineering

Best Scour Monitoring Technologies

Mike Jones 9 min read
On this page

Inspection tells you what the bed looked like on the day someone visited. Scour, though, peaks during the flood and the hole often refills as the water drops, so the deepest scour a bridge sees may never be on the record. HEC-23 puts it plainly: visual monitoring during a flood and inspection after it “cannot fully determine that a bridge is safe.”

Fixed monitoring closes that gap. An instrument attached to a pier or buried in the bed takes readings through the event, and can send an alarm while there is still time to close the road.

This list covers fixed monitoring. Portable tools carried to the bridge for a periodic survey (probes, boat-mounted sonar, multibeam, GPR) are covered separately in best bridge scour inspection methods. HEC-23 draws the same line: fixed instruments for frequent or continuous watch, portable instruments for occasional measurements and wider coverage.

How we ranked them

The primary sources are FHWA HEC-23 (third edition, 2009, Chapter 9), HEC-18 (fifth edition, 2012, Chapter 10), NCHRP Report 396 (Lagasse et al., 1997), its companion installation manuals (NCHRP Reports 397A and 397B), and the NCHRP synthesis of state practice by Hunt, which HEC-23 summarizes. We weighted:

  • Field record. How widely the device has actually been installed and kept running by bridge owners.
  • What it reports. A full time history of scour and refill is worth more than a single “maximum depth reached” reading, which in turn is worth more than a yes or no at one elevation.
  • Survivability. Debris and ice caused most of the damage and interference owners reported in the synthesis survey.
  • Installability on the bridge and bed you actually have.

The NCHRP 21-03 project that produced Report 396 set mandatory criteria that are still a good checklist: install on or near a pier or abutment, measure maximum scour within about ±1 ft, read from above water or remotely, and work during floods.

At a glance

#TechnologyReportsField recordMain weakness
1Fixed sonarContinuous bed elevation, scour and refillMost common; 70 of 120 instrumented sitesDebris, ice, air entrainment
2Magnetic sliding collarMaximum scour depth reachedSecond; 21 sitesDriven-rod installation; no refill record
3Tilt sensorMovement and rotation of the structureIn use; Caltrans example in HEC-23Detects the effect, not the scour
4Float-out deviceThat scour reached a preset depthIn use by 2007Hard to install under water; one-shot
5Sounding (falling) rodBed lowering at the rodEarly installationsSinks into sand beds
6Time domain reflectometryBed-water interface along buried probesOne of five types in use in the 2007 surveyDriven-rod limits; specialist interpretation
7Fiber optic (FBG) pilesBed level from strain profile, including refillResearch and field trialsNot an off-the-shelf system
8Emerging: smart rocks and othersLocation of rocks rolling into the holeResearchNot yet a standard tool

1. Fixed sonar monitors

A transducer mounted on the pier or abutment face measures the distance to the bed from the travel time of a sound pulse, on a schedule set in a data logger, and sends the result to a master station or over a cellular or satellite link. HEC-23 notes that early systems used off-the-shelf fish finders and that current ones range from those to “smart” transducers.

The decisive advantage is that sonar tracks both scour and refill, giving a time history of the event. HEC-23, summarizing the NCHRP synthesis, reports sonar at 70 of the 120 bridge sites identified with fixed monitors, by far the most common choice. NCHRP Report 397A is the installation, operation and fabrication manual for the low-cost sonar system developed under NCHRP 21-03.

Best fit: tidal and coastal crossings, which HEC-23 says suit sonar best, and any bridge where the owner wants to see how the hole develops and refills.

Worst fit: debris-laden and icy rivers. HEC-23 notes that debris or ice collecting between the transducer and the bed can make the system inoperative, and that air entrainment in turbulent flow degrades readings.

2. Magnetic sliding collars

A rod or mast is fixed to the pier face and driven or augered into the bed, and a collar carrying magnets rests on the bed around it. As the bed scours, the collar slides down the rod. Early versions were read with a manual probe dropped down the rod; automated versions have magnetically activated switches along the rod that a data logger reads as the collar passes. NCHRP Report 397B is the manual for the device.

HEC-23 lists it at 21 of the 120 sites. It also notes that the automated version places most of the device below the bed, which makes it less vulnerable to ice and debris, and that driven-rod devices can be used on sloping piers and spill-through abutments where face-mounted instruments struggle.

Best fit: debris-prone rivers where a face-mounted sonar would not survive, and sloping or awkward substructure geometry.

Worst fit: anyone who needs the refill history. The collar stays at the deepest point reached, so it records maximum scour only. Hard or cobble beds also complicate driving the rod, and pre-drilling or jetting over water adds cost.

3. Tilt sensors

Paired clinometers on a pier or abutment measure rotation along and across the bridge. They do not measure scour at all; they measure what scour does to the structure. HEC-23 notes that they mount on the superstructure and above-water substructure, which makes them easier and cheaper to install than most fixed instruments.

The catch, per HEC-23: the bridge must be redundant enough to tolerate some movement without failing, and setting the alarm angle is hard because traffic, temperature, wind and hydraulic loads all move a bridge. Caltrans handled this by recording each pier’s normal movement for several months, ideally a year, before setting alarm thresholds.

Best fit: bridges where instruments in the water will not survive, and as a second, independent alarm alongside a bed-level monitor.

Worst fit: non-redundant structures, where by the time a pier tilts measurably there may be no margin left.

4. Float-out devices

Radio transmitters buried in the bed at chosen depths. When scour reaches one, it floats free, activates, and transmits its identification number to a receiver on the bridge, which tells the owner which depth and location has been reached. HEC-23 describes the sensor as drawing zero current while buried, with a lithium battery giving a nine-year life expectancy in the inactive state.

HEC-23 calls float-outs simple to fabricate and relatively inexpensive, and notes they are particularly easy to install in dry beds, during installation of an armoring countermeasure such as riprap, or during construction of a new bridge.

Best fit: ephemeral streams, new bridges, and new armor installations where the owner wants to know if a design scour elevation is ever reached.

Worst fit: retrofits in deep flowing water, where HEC-23 says underwater installation would be difficult. Each device reports once; it gives a threshold alarm, not a history.

5. Sounding rods (falling rods)

Gravity-based probes whose foot rests on the bed; as the bed lowers, the rod drops and a counter records the change. HEC-23 notes they are susceptible to sinking into sand beds, which affects accuracy, and recommends them for coarse-bed streams or for monitoring riprap stability, citing a New York installation that used Brisco Monitor sounding rods to watch riprap movement at a pier.

Best fit: gravel and cobble beds, and watching whether an existing armor layer is moving.

Worst fit: sand-bed rivers, unless the foot is enlarged; HEC-23 notes a large base plate may help.

6. Time domain reflectometry (TDR)

An electromagnetic pulse is sent down two parallel pipes buried vertically in the bed. Part of the pulse reflects where the surrounding medium changes, at the soil-water interface, and the travel time gives the bed elevation. HEC-23’s example comes from the U.S. Army Corps of Engineers Cold Regions Research and Engineering Laboratory, where TDR was used to correlate bed changes with hydraulic and ice conditions.

Best fit: research-grade sites and cold-region rivers where ice-scour interaction is the question.

Worst fit: stony or hard beds, since HEC-23 notes all driven-rod devices, including TDR, are limited by bed and substrate conditions; and programs without staff to interpret the waveforms.

7. Fiber optic sensors (fiber Bragg gratings)

Strain sensors along a slender pile driven beside the foundation. The pile bends under flow, and the point of maximum strain sits near the bed level, so the strain profile tracks scour and deposition. Louisiana’s LTRC Final Report 535 (Cai et al., 2015) developed this approach, installed two 18-ft instrumented piles beside a field bridge, and found the system performed well enough to recommend further applications. The report also notes that its readings were taken on field trips and that online, continuous monitoring still needed to be developed.

Best fit: owners willing to run a pilot with a research partner, particularly on coastal and bayou bridges, where electromagnetic interference immunity and multiplexing appeal.

Worst fit: anyone who needs a commercially supported, remotely reporting system today.

8. Emerging: smart rocks and other research devices

Missouri University of Science and Technology has researched “smart rocks,” concrete units with embedded magnets or electronics placed at a foundation to roll into the deepest part of a developing scour hole, where their position can be located from above (project page). The concept is attractive because it pairs monitoring with rock armor. Other research directions, such as inferring scour from changes in a structure’s natural frequency, appear in the literature too. None is yet a standard DOT tool.

Best fit: research partnerships.

Worst fit: a plan of action that needs a proven alarm this flood season.

Choosing, and what monitoring cannot do

HEC-23’s advice is to treat instrumentation as a toolbox: no single device works everywhere. A few rules follow from the sources:

  • Put the instrument where the predicted hole will be. HEC-23 warns that the location of maximum scour may shift away from where an instrument was installed. The predicted scour geometry, covered in predicting scour depth, tells you where to aim.
  • Ground-truth fixed instruments with portable surveys, as HEC-23 recommends.
  • Budget for maintenance. Owners in the synthesis survey said debris and ice damage was more frequent and costly than they expected.
  • Write the response into the plan of action. A monitor that alarms with nobody assigned to act is only a record. See scour critical bridges.

Monitoring manages a scour risk; it does not remove it. When the readings say the bed is going, the options are the countermeasures compared in best bridge scour protection products and, for the flood itself, best emergency scour response products for DOTs. FES Solutions supplies rock bags for that kind of work (see our bridges page), and a float-out or sounding rod placed with new armor, as HEC-23 describes, is a sensible way to learn whether the armor is holding.

Questions about protecting a bridge your monitors are flagging? Contact us.

FES Solutions is a supplier, not the engineer of record. This article is general engineering background, not a site-specific design. Conditions vary, and the design decision for your project belongs to the engineer of record. Where rock bags are not the right answer.

Written by
Mike Jones
Engineering Manager, FES Solutions

Mike Jones is Engineering Manager at FES Solutions. He holds a BS in civil engineering and an MS in hydrology, and spent 15 years with engineering firms and as an independent consultant on drainage and erosion control projects.

Specifying scour protection?

Tell us the site conditions and we'll come back with sizing, lead time, and pricing within one business day.

Call