FES Solutions manufactures Texas Tuff Rock Bags and publishes this list. We rank our own product first; read the “worst fit” note under each entry, including ours.
This list is for bridge owners, hydraulic engineers and maintenance managers choosing armor for an existing pier or abutment. It covers products that sit on or in the bed and resist the flow. It does not cover the other ways of dealing with scour, which are often better, and we say so below.
The framework is FHWA’s HEC-23, Bridge Scour and Stream Instability Countermeasures (third edition, 2009). HEC-23 sorts countermeasures into four groups: hydraulic countermeasures (river training structures, plus armoring), structural countermeasures (foundation strengthening and pier geometry changes), biotechnical countermeasures, and monitoring. Everything on this list belongs to one sub-group, armoring countermeasures, which HEC-23 splits into rigid and flexible/articulating revetments and bed armor, and local scour armoring at individual piers and abutments.
That matters for two reasons. First, armor is only one of four answers. A guide bank that fixes the approach flow at an abutment, a deeper foundation, or a monitoring program with closure triggers may be the right answer at your structure. See the scour countermeasure families. Second, HEC-23 publishes design guidelines for most of the products below. It does not publish one for rock-filled mesh bags, including ours. We come back to that in our own entry.
How we compared them
We scored each option on the things that decide performance at an existing bridge:
- Placement in the wet. Can it go in without a cofferdam or dewatering?
- Conformance to a changing bed. HEC-23 notes that rigid armor “do[es] not have the ability to conform to changes in the supporting surface” and is “subject to failure due to undermining,” while flexible armor adjusts to settlement but can fail by displacement. At a pier, the bed does change.
- Local fill. Can it be built from stone or sand available near the site?
- Permeability and filter needs. What has to go between the armor and the bed?
- Repairability. Can a damaged section be fixed without rebuilding the whole blanket?
- Published design guidance. Is there an HEC-23 design guideline, and does the vendor publish test data?
- Track record at bridges.
These criteria favor flexible, wet-placeable armor, because that is what a retrofit at a working bridge usually needs. They also include published design guidance, where we score worst of anyone on this list. Weight them for your own site.
Comparison at a glance
| Option | HEC-23 design guideline | Placed in the wet | Follows a changing bed | Local fill | Main limit |
|---|---|---|---|---|---|
| Texas Tuff Rock Bags | None for bagged rock | Yes | Yes, unit by unit | Yes (stone) | Rated current per size; no published stability tests |
| Rock riprap | DG4, DG11, DG14 | Yes | Yes | Yes, if size available | Needs large, durable stone and a filter |
| Partially grouted riprap | DG12 | With special grout and QC | Partly | Yes | Grouting quality control |
| Articulating concrete block mats | DG8 | Difficult | Within limits of the mat | No (precast) | Subgrade preparation and edge detailing |
| Grout-filled mattresses | DG9 | Yes | Before grout sets; limited after | No (pumped grout) | Limited pier track record per HEC-23 |
| Gabion mattresses | DG6, DG10 | Difficult | Yes | Yes (smaller stone) | Wire abrasion and corrosion |
| Grout/cement-filled bags | DG13 | Yes | Yes, bag by bag | Partly | No quantitative design procedure |
| Concrete armor units | DG19 | Yes | Interlocked matrix | No (precast) | Supply and handling of manufactured units |
1. Texas Tuff Rock Bags (FES Solutions)
Rock-filled units made of Raschel-weave virgin polyester mesh with 3-ply polyester rope and a single lifting point. Standard sizes run from 1-Ton (about 1.5 m diameter) to 8-Ton (about 3.0 m), with custom builds up to 25 tonne. They are filled on site with local stone, lifted by excavator or crane, and placed in the dry, from a barge, or underwater without dewatering. Placed around a pier or along an abutment toe, they settle into a developing scour hole and stay in contact with the bed rather than bridging over a void. Individual units can be lifted out and replaced. Service life is approximately 100 years installed in water and submerged out of direct UV (EN 12447).
Within HEC-23 they would sit under flexible local scour armoring, but there is no HEC-23 design guideline for them. HEC-18 scour computation and HEC-23’s general principles (plan extent, filter, toe and flank terminations) transfer. The unit sizing procedure does not. See HEC-18 and bagged armor design and our own rock bags vs. riprap for bridge scour.
Best fit: retrofit armor at existing piers and abutments where the site cannot be dewatered, where access limits the equipment you can bring, where large riprap is expensive to source but smaller local stone is not, and where the bed is expected to keep moving.
Worst fit: any location where the design velocity exceeds the rated grouped current of the largest applicable size, or where the design needs a rigid monolithic mass. Also any job where the reviewer requires a design that follows a specific HEC-23 guideline, because none exists for this product, and we publish test methods but no stability test values or scour-reduction figures. Where good riprap is local, cheap and easy to place, riprap is often the better buy. See when not to use rock bags.
2. Rock riprap
Loose, graded, angular stone placed over a granular or geotextile filter. It is the reference countermeasure in HEC-23, with design guidelines for revetment (DG4), piers (DG11) and abutments (DG14), and it is what most state specifications are written around. No vendor to name: it comes from local quarries.
HEC-23 is candid about how it is misused. It says riprap at piers is a retrofit measure, not a substitute for foundations below expected scour depth on new bridges, and that “the practice of heaping stones around a pier is not recommended because experience has shown that continual replacement is usually required.”
Best fit: almost anywhere suitable stone of the required size is available at reasonable haul distance, the design has a proper filter, and the owner has an inspection program that will notice when stone goes missing. See when riprap is the right choice.
Worst fit: sites where the required stone size is not locally available, or where riprap cannot be placed to its design thickness and extent. Riprap that is not maintained stops being protection; the 1987 Schoharie Creek collapse is the standing example.
3. Partially grouted riprap
Riprap whose voids are partly filled (HEC-23 says one third to one half) with a cement-based grout, gluing stones at their contact points while leaving the layer permeable and somewhat flexible. HEC-23 DG12 covers it at bridge piers and notes it allows smaller rock than loose riprap for the same conditions.
Best fit: sites where the riprap size needed for loose placement is not available but smaller stone is, and where the contractor can control grout mix and placement.
Worst fit: jobs without the quality control that grouting needs. Too much grout turns it into a rigid slab that can be undermined; too little gives you loose riprap with extra cost. Placement under water needs a specific grout and procedure.
4. Articulating concrete block mats (e.g. Contech ArmorFlex)
Precast concrete blocks that interlock, are cabled together, or both, forming a continuous mat laid over a geotextile. HEC-23 DG8 covers bank and bed armor and pier protection, and ASTM D7277 is the standard performance test the guideline cites. Contech ArmorFlex is a well-known cabled system; Contech states that ArmorFlex and A-Jacks are accepted pier scour countermeasures under FHWA guidelines. See our rock bags vs. articulated concrete blocks.
Best fit: channel linings, abutment spill slopes and larger bed-armor areas where the subgrade can be graded and the mat laid in the dry or in shallow, controlled conditions. Vendor-tested hydraulic design parameters are a real advantage in a review.
Worst fit: deep or fast water where the subgrade cannot be prepared, and irregular beds around existing footings. Like any blanket, it depends on well-detailed edges and a sound filter.
5. Grout-filled mattresses (e.g. Synthetex Hydrotex)
A double-layer synthetic fabric form, laid in place and pumped full of fine-aggregate concrete, often with internal cables so it cures as an articulating block mat. HEC-23 DG9 notes the fabric “can be completed quickly, without the need for dewatering” and suits sites with little room for equipment, but also that there is “limited field experience” with these mats as a pier scour countermeasure. Synthetex Hydrotex markets articulating block mats, grout bags and pile jackets for bridge piers and abutments.
Best fit: abutment slopes and channel armor with limited headroom or access, where pumping grout is easier than placing heavy units.
Worst fit: a bed that is expected to keep lowering after the grout sets. Once cured, the mat follows the bed only as far as its articulation allows, and HEC-23 prefers products with filter points and small ducts for that reason.
6. Gabion and Reno mattresses (e.g. Maccaferri)
Wire-mesh containers, compartmented and laced together on site, filled with stone smaller than loose riprap would need. HEC-23 covers them in DG10 (gabion mattresses, including at piers) and DG6 (wire-enclosed riprap mattress). Maccaferri’s Reno Mattress is the best-known branded version. See when a gabion is still the right answer.
Best fit: sand- or fine-bed streams with non-corrosive water, bank and channel linings, and sites where only smaller stone is available.
Worst fit: gravel-bed streams. HEC-23 DG10 says gabion mattresses “are not appropriate for gravel bed streams” because of abrasion by coarse bed load, that the water must be non-saline and non-acidic, and that durability of the wire at bridge piers “has not been demonstrated.” Also hard to assemble under water.
7. Grout and cement-filled bags
Fabric bags filled with grout or a cement mix, placed individually. HEC-23 DG13 says they have historically been used “to fill in undermined areas around bridge piers and abutments,” are relatively easy to install, and can shift with the bed. It reproduces Maryland State Highway Administration installation guidance (single layer where possible, filter fabric beneath, no bag larger than 3 ft by 4 ft by 1 ft). Several fabric-form suppliers, including Synthetex, sell grout bags for this use. See rock bags vs. grout bags.
Best fit: filling voids under an undermined footing and small local repairs where access is by hand or small equipment.
Worst fit: designed armor for a large area. HEC-23 states that “a precise quantitative factor of safety design procedure is not normally completed” for grout bags and that bag size is usually chosen by engineering judgment.
8. Concrete armor units (e.g. Contech A-Jacks)
Manufactured three-dimensional concrete shapes that interlock into a permeable matrix. HEC-23 DG19 lists A-Jacks, tetrapods, dolos and similar units, and says their main advantage is greater stability than riprap for the same weight because of interlock, which matters “when riprap of a required size is not available.” Contech A-Jacks are marketed for pier and abutment toe protection.
Best fit: high-energy sites where the riprap size needed is unavailable, and steeper slopes where interlock helps.
Worst fit: remote sites where hauling precast units is the hard part, and small jobs where the cost of manufactured units outweighs their stability advantage.
Which one for which site
- Existing pier, cannot dewater, bed still moving: rock bags or riprap with a placed filter; grout bags for voids under the footing.
- Good local stone, easy access, strong inspection program: riprap. It is the reference case for good reasons.
- Only small stone available: partially grouted riprap, gabion mattresses (fine-bed, non-corrosive streams), or rock bags filled with that stone.
- Abutment spill slope or channel lining in controlled conditions: block mats or grout-filled mattresses.
- Very high energy, no large stone: concrete armor units, or check whether armor is the answer at all.
- Approach flow or contraction driving the problem: look at guide banks, spurs, or the opening itself before any armor. See stabilizing a scoured abutment.
Whatever you choose, the details that decide whether it lasts are the filter, the plan extent and the terminations, not the brand. Why scour protection fails covers those, and the bridges application page shows where our product fits.
If you want a straight answer on whether rock bags suit your structure, including “no,” send the site details through the quote form.