This page explains how a rock bag installation is sized and laid out from hydraulic data, and where that work sits inside the US federal framework for bridge scour. It is written for the engineer preparing or reviewing a design, and for the agency reviewer who needs to know what the design is founded on.
Two things at the top. The product does not set the design basis — the design event, return period and acceptance criteria come from the owner or the reviewing agency, and sizing confirms the selected unit sits above the loading that basis produces. And the federal guidance here is specific about what it covers, so this page is equally specific about where it stops. Overstating it is the fastest way to lose a reviewer.
If you have a design velocity and depth already, the sizing calculator will get you to a starting size and the flow velocity method explains the basis behind it. If the site looks marginal, read when not to use rock bags first.
What the engineering team needs to size a job
The core data set
Design velocity, flow depth and the design event are the minimum. Wave conditions are added where the site is coastal, estuarine or exposed to fetch. Channel geometry, longitudinal slope and bed material description improve the answer materially, because they describe how the flow field is distributed rather than just how fast it is.
Why a model output beats a single number
A reach-average velocity hides the thing that governs — where the flow concentrates. Model output shows the distribution across the section and around the obstruction, which is what the armor is sized against. Send the output rather than a summarized figure, and say which model and which run it came from.
If part of the data set is still being collected, send what exists through the quote form. Gaps get named rather than filled with assumptions; a plausible-looking guess is harder to unwind later than an acknowledged gap.
Where this sits in the US federal framework
The regulatory hook
For bridges, this subject is not optional. The National Bridge Inspection Standards at 23 CFR 650.313(o) require the owner to “perform a scour appraisal for all bridges over water” and document it in the bridge file, re-appraising when conditions change. For bridges determined scour critical or to have unknown foundations, the same provision requires a documented scour plan of action for deployment of countermeasures.
The regulation says scour appraisal procedures “should be consistent with” Hydraulic Engineering Circulars 18 and 20. Note the verb: the appraisal is mandatory; conformance with the circulars is a should. HEC-18 and HEC-23 are FHWA guidance, not standards incorporated into federal regulation. A DOT reviewer will know that distinction, so it is better acknowledged than blurred.
HEC-18 — evaluating the scour
Evaluating Scour at Bridges, HEC-18, Fifth Edition, April 2012, FHWA-HIF-12-003. It remains the current edition; there is no sixth, so it should not be described as recently updated.
HEC-18 governs the load side: how deep the scour is predicted to be and what conditions act at the structure. Total scour is assembled from three components that HEC-18 adds together — long-term degradation of the river bed, contraction scour at the bridge, and local scour at the piers or abutments. Two points of precision are worth carrying into a submittal:
- Aggradation is not a component of total scour. HEC-18 is explicit that aggradation involves deposition and “is not considered a component of total scour,” while degradation “contributes to total scour.” “Long-term aggradation and degradation” is the name of the analysis; only degradation enters the sum.
- The Fifth Edition deleted the term “general scour.” Older literature using it as a synonym for contraction scour is out of date.
HEC-18 also requires other scour types — bend, confluence, variable downstream control — and lateral stream migration to be assessed. The result is plotted as a total scour line on the cross section and the foundation checked against it.
Critically, HEC-18 does not contain countermeasure design methods and says so. Section 3.7 states that the design of stabilization works “is beyond the scope of this document,” and routes the reader to HEC-23. What it carries on the countermeasure side is design philosophy for new versus existing bridges, and plan of action policy — not sizing or layout.
HEC-23 — designing the countermeasure
Bridge Scour and Stream Instability Countermeasures: Experience, Selection, and Design Guidance, HEC-23, Third Edition, September 2009, in two volumes: Volume 1, FHWA-NHI-09-111 and Volume 2, FHWA-NHI-09-112. No fourth edition exists. Volume 1 covers selection, riprap design, specification and quality control, and biotechnical countermeasures; Volume 2 contains 19 design guidelines in six sections.
HEC-23 is where extent, edge treatment and filter requirements come from. Those principles apply to a bagged armor layout even though the design guidelines are written around more traditional countermeasures — which brings us to an important limit, below.
The AASHTO role
AASHTO supplies the design specification into which the predicted scour depth is carried — the load and resistance framework governing foundation bearing depth and pile penetration after the design scour event. AASHTO is a standards-writing association of the state DOTs with no independent regulatory authority; its documents acquire federal force where FHWA incorporates them by reference, or where a state adopts them.
That produces an edition distinction worth getting right. The 10th Edition of the AASHTO LRFD Bridge Design Specifications was released in December 2024 and is the latest published edition. The edition incorporated by reference at 23 CFR 625.4(d)(1)(v) is the 8th Edition, 2017. Both statements are true and they mean different things. States adopt newer editions on their own schedules, so confirm which edition your project is held to.
Net: FHWA regulation requires the appraisal and the plan of action and points to HEC-18 and HEC-20 for appraisal method, and to HEC-18 and HEC-23 for the scour plan of action; AASHTO LRFD governs how the scour depth is carried into foundation design; HEC-23 supplies countermeasure methods as guidance; the installation is permitted separately by the Corps and specified by the state DOT. See the permitting guide and bridge scour applications.
The HEC-23 countermeasure groups, and where bagged armor sits
HEC-23 organizes countermeasures into four groups by functionality with respect to scour and stream instability:
- Group 1 — Hydraulic countermeasures, split into 1.A river training structures (transverse, longitudinal, areal) and 1.B armoring countermeasures (revetments and bed armor, subdivided rigid and flexible/articulating; plus local scour armoring)
- Group 2 — Structural countermeasures (foundation strengthening, pier geometry modification)
- Group 3 — Biotechnical countermeasures
- Group 4 — Monitoring (fixed instrumentation, portable instrumentation, visual monitoring)
The split within Group 1 is functional. River training structures modify the flow; armoring countermeasures resist the erosive forces caused by it, acting as a resistant layer to hydraulic shear stresses that protects the more erodible material underneath without necessarily altering the hydraulics of a reach. River training structures are classified by orientation to flow; armoring countermeasures vary mainly by material type.
Conceptually, a rock bag revetment or bed apron is an armoring countermeasure in the flexible/articulating branch of Group 1.B: discrete units that resist shear as a mass and conform to the bed rather than spanning it. That is a description of function, not a citation. HEC-23 notes that rigid systems fail by undermining while flexible and articulating systems fail by removal and displacement of the armor material — which is why unit weight and toe founding matter more than surface continuity here.
What HEC-23 does and does not say about geotextile containers
This deserves to be stated plainly, because it is easy to get wrong in either direction and a reviewer who knows the document will check.
What HEC-23 does say. It recognizes sand-filled geotextile containers as an accepted technique for placing a filter beneath a riprap armor layer in flowing or deep water (Volume 1, Section 5.3; Volume 2, Design Guidelines 11 and 12). The controlling sentence, repeated across those locations, is that such containers “provide a convenient method for controlled placement of a filter in flowing water,” and that the method can also partially fill an existing scour hole where placement must occur under water. HEC-23 gives fabric guidance — non-woven needle-punched, minimum mass per unit area of 500 grams per square meter for roughly one-tonne units, and 200 grams per square meter for a practical minimum 200-lb container covering about 6 to 8 square feet. It notes that in deep water or currents greater than 3.3 ft/s German practice calls for sand-filled geotextile containers, that the container must be sized so the expected hydraulic load will not transport it during placement, and that **once placed, the containers are overlaid with the final armoring material.dropping 32 containers around a pier and overlaying them with riprap. DG 11 reports that these tests confirmed the containers could be fabricated locally and placed with standard commercially available equipment — a finding about fabricability and placement rather than integrity under load; the separate partially grouted riprap testing at DG 12 is where the containers are reported to have remained intact.
What HEC-23 does not say. It provides no design guideline for rock-filled or gravel-filled geotextile bags used as the armor layer. There is no HEC-23 sizing method for bagged armor, and nothing in the document should be read as FHWA endorsement of it.
One point that is frequently misused. Design Guideline 13, “Grout/Cement Filled Bags,” is a different product — cement-grout-filled bags, a rigid system, for abutment protection and filling undermined areas. DG 13 itself states that a precise quantitative factor of safety design procedure is not normally completed for grout filled bags, and that engineering judgment is more often used to select a bag size that will not be removed by the flow. It originated as a state agency submission, and HEC-23’s Volume 2 introduction places it explicitly among the guidelines that “have not been evaluated, tested, or endorsed by the authors of this document or by the FHWA.” DG 13 is not a warrant for rock-filled bags and is not evidence of federal endorsement of any bagged system.
The honest position: HEC-23 supplies the framework — countermeasure classification, extent and edge treatment principles, a categorical filter requirement — and validates geotextile containers for filter placement under flow. It does not supply a sizing method for bagged armor. FES sizing is published as grouped current resistance derived from its own testing, not as a HEC-23 design guideline, and should be presented to a reviewer that way. The test data page sets out the methods and laboratories behind those figures.
The filter requirement, and why it is not optional
HEC-23 Volume 2 states the requirement categorically: “An appropriate granular or geotextile filter is essential for any countermeasure requiring a protective armor layer.” Filter design guidance is Design Guideline 16.
HEC-23 also observes, citing NCHRP research, that filter design criteria has typically been the most overlooked aspect of revetment riprap design. The governing rule is simple and frequently violated: the hydraulic conductivity of the filter should never be less than the material below it, whether base soil or another filter layer. A less permeable filter allows hydrostatic pressure to build beneath the armor.
Points that carry into a bagged armor layout:
- Granular filters. HEC-23 recommends the Cistin–Ziems method over Terzaghi, on the grounds that the Terzaghi approach was developed for well-graded sands and may not be widely applicable to other soil types. Minimum thickness is four times the d₅₀ of the filter stone or 6 inches, whichever is greater, increased by 50 percent when placing under water.
- Geotextile filters. Only woven monofilament or non-woven needle-punched geotextiles should be considered; slit-film, spun-bonded and other types are not suitable as filters. A woven monofilament should have a Percent Open Area of at least 4 percent; a non-woven needle-punched fabric should have porosity of at least 30 percent and mass per unit area of at least 400 grams per square meter.
- Filter extent under pier riprap. The filter should not extend fully beneath the riprap, but terminate two-thirds of the distance from the pier to the edge of the armor.
A note for anyone quoting HEC-23’s filter test table: written in 2009, it specifies ASTM D4833 for puncture. That method has since been retitled for geomembranes and its geotextile application discontinued; ASTM D6241 is the current geotextile puncture method. Quote HEC-23 as written and footnote the change rather than silently substituting the newer designation.
Site-level practice is covered under geotextile underlay in the installation guide.
From hydraulic numbers to a bag size
Translating a specified riprap D50
Not by direct equivalence. Riprap stability is governed by the individual stone; a filled bag resists as a whole unit, which is why FES publishes grouped current resistance rather than a nominal diameter. Take the design velocity the D50 was derived from and size against that instead. The flow velocity method works through the substitution.
Bed shear stress
Shear stress is the parameter many channel stability calculations are expressed in, and it is related to but not interchangeable with velocity. Because the published resistance figures are stated as grouped current velocity, a design worked in shear needs the corresponding velocity derived for the design section before it can be checked against them.Models that report boundary shear generally also report velocity at the same section, so the design velocity is usually available directly. Note that shear in a 1D model is typically computed from hydraulic radius and energy slope rather than from velocity, so where velocity is not reported it must be derived for the section rather than back-calculated from shear.
Depth-averaged versus local velocity
Use the local velocity at the structure — that is what loads the armor. Depth-averaged approach velocity understates conditions at a pier, an abutment or an outfall because the structure accelerates and concentrates the flow, and taking the approach figure is one of the more common ways a design ends up undersized.
Taking design velocity from a HEC-RAS model
Yes, provided it comes from the right place. Output at a cross section upstream of the structure is not the velocity at the structure, and a one-dimensional model does not resolve local acceleration around a pier at all. Two-dimensional output, or an explicit local velocity adjustment applied to 1D output, is more defensible. Note which you used when you send the data — it changes how the number should be read.
Design storm and return period
That comes from the project’s design basis or the reviewing agency, not from the product. A state DOT bridge, a municipal outfall and a private lakefront bank are held to very different standards. On the product side, grouped current resistance is a limit rather than a target: the selected size should sit above the velocity produced by whatever event governs, with the margin decided by the designer.
Scour depth, layout, and the rest of the model
Scour prediction drives the layout, not just the size
Scour depth is predicted through the standard contraction, local pier and abutment equations, normally within the HEC-18 framework. It drives layout because armor has to extend deep and wide enough that its own edge is not undermined by the scour hole it exists to prevent. Protection stopping short of the predicted depth fails from the edge inward regardless of how well the units are sized. Toe elevation and apron extent follow from the scour prediction, and they are usually where a marginal design goes wrong.
Representing the armor in the hydraulic model
For most bank and outfall work, no — the protection follows the existing line closely enough that it does not materially change conveyance. It matters where the armor occupies significant flow area: a narrow channel, or a thick section built out from a bank. There the loss of conveyance should be checked, because it can raise upstream water levels and because it interacts directly with any floodway no-rise requirement. Establish that constraint before the layout is finalized.
Effect on hydraulics elsewhere in the reach
Armoring changes where the erosion happens. Protecting one bank without addressing the opposite one sometimes relocates the problem, and armoring a reach can move erosion to the unprotected section immediately downstream. This is why layouts pay attention to tie-ins at both ends and why terminations are taken into stable ground. River and streambank work covers how a section is terminated so the transition does not become the next failure point.
Freeboard and overtopping
Set the top of the protection against the water level that governs, not the average. On a bank revetment that usually means the design flood level plus an allowance; on a coastal slope, the design still water level plus wave run-up. Armor stopping below the level the water actually reaches will be attacked from behind, eroding the bank above and then removing support from the units themselves.
Conditions that change the answer
Supercritical flow at steep sections and spillways
Supercritical flow brings high velocities and the possibility of a hydraulic jump inside the protected reach, concentrating energy at a location that has to be identified rather than averaged over. The jump moves with discharge, so check a range of events rather than the design peak alone. See stormwater and drainage.
Turbulence at structures
Handled mainly through using local rather than reach-average velocity, and through extending the protection far enough that its edge sits outside the disturbed zone. Where a structure creates a persistent vortex, the response is a heavier size locally rather than uniformly upgrading the whole layout.
Combined wave and current
Check these as a combination rather than separately. The current shifts the bed while the waves supply cyclic uplift, and the two together are more demanding than either alone. Port approaches, exposed coastal frontages and estuarine locations are the usual candidates. Supply both data sets so the governing case is identified rather than assumed.
Slope steepness
Steepness affects stability of the placed units as much as the hydraulics: a steeper face increases the gravity component acting to move a unit downslope and reduces contact area between neighbors. Steep slopes generally need a heavier size than velocity alone suggests, and they raise the importance of a properly founded toe.
What to send us
For a sizing review: structure and application type, design velocity and flow depth with a note on where each came from, the design event and its source, wave data where relevant, channel geometry and slope, bed material, predicted scour depths if a scour evaluation exists, and any agency criteria the design is held to.
Send it through the quote form, or call +1 512-766-6608. Published dimensions, weights and volumes are on the specifications page.
Related: Sizing calculator · Flow velocity sizing method · When not to use rock bags · Bridge scour protection · Permitting guide · Specifications